Trudy’s RET Experience at UCSD

I am a life science teacher, and recently, our district adopted the new NGSS standards. This research project and lesson fit in well with the standards and with the spirit of the new standards.

In my project, I improved on a technique I saw on youtube to build a cell phone spectrophotometer to view plant pigments. As part of my project, I dug into how a spectrophotometer works, I learned more about photosynthesis, and I learned a lot about light. To design a better cell phone spectrophotometer, I did experiments as outlined below.

Experiments were conducted in Peter Ilinyhk’s lab. A web page[1] and YouTube video[2] were found on how to make a spectrophotometer out of a cell phone very simply. I experimented with the idea to determine how to build one that would give the students the best results. To determine which procedure was best, I used data generated with different types of cell apps and designs for the box to create standard curves using Beer’s law to estimate known concentrations of solutions. Several tests were done as shown below, with the best results achieved using method #3.

  1. 6/29/17 Methods and Trial 1
    1. Reproduce standard curve using the exact procedure as in the video (see footnotes) using green paper and red food coloring. Graphed raw data and absorbance.
    2. Calculations were performed in Excel as follows: G value was collected directly from cell phone using paper or light as close to complementary as possible. Complementary colors have the highest peaks of absorbance. This could not be controlled with the paper experiments, but later, using the online wavelength to color relationship app, the best color can be transmitted directly through the computer screen. Absorbance was calculated by  Ay = -log10(I/Io) where Ay is the absorbance of light with wavelength y and I/Io is the transmittance of the test material[3]. Io is the intensity of the light being passed through a blank (solvent used), and I is the intensity of the light passing through the sample.
      For example, with the red solution, the green value of the blank was used as I0, which would be high for the blank, while the I was the green value of the red test solution, which would transmit less of the green light because it was absorbed by the red liquid.
    3. Using Beer’s law, and known concentrations of the red liquid, a standard curve could be drawn and then used to determine the accuracy of the spectrophotometer.
    4. All data were collected and analyzed in this Excel spreadsheet. You must open this in Excel, does not read file correctly online! https://drive.google.com/file/d/0B_c27o3SYJ3NeTd4al9qT2xYMUE/view?usp=sharing
    5. I chose the ColorMeter Free version over about 9 other spec and colorimeter apps. This one is really easy to use. Use one of the RGB meter apps on the cell phone to get readings. Use paper to reflect light closest to complementary color of solution for peak absorbance.
    6. I then cross-checked the results using the Vernier SpectroVis spectrophotometer. I looked for a peak of absorbance and chose that value as the wavelength to focus on. It was in the green spectrum.

Some issues I had with setting up the spectrophotometer: inside of the box needs to be covered in black paper, it works better that way. I simply lined the box with black construction paper.

Green paper with red dye solution gave results pretty similar to the results I got with the store bought spec.

I made the following concentrations of solutions:

  1. 1000 ppm = 2 drops food coloring/100 ml of deionized water
  2. 500 ppm = serial dilutions were made using the stock solution above
  3. 250 ppm
  4. 125 ppm
  5. 62.5 ppm
  6. 333 ppm
  7. 0 ppm using deionized water

Got a huge % error, but it was consistent in both store and home spec. I think I measured the solutions incorrectly.

3.      17. Method 2: Using a Filter and More Testing with Colored Paper

  • Did same experiments 2 drops per 100 ml with the same serial dilutions of 50% each time. Remade the solutions. Unknown is 333 Continue to get huge % error in both store and home. Perhaps another problem with measuring the solutions? I also only did one trial, so could have just been a sample size issue.  There also seems to be a problem with the reflected light using the paper.
  • I placed transparent colored film over the outside of the boxes and used direct light to measure absorbance of red liquid using a green filter. I could not get good results with the filters. Data accuracy was poor, especially at low concentrations. Phone color meter was saturated with light. When using reflected light, there did not seem to be enough light passing through the filter to get an accurate reading.

4.       7/10/17. Method 3: Using White Paper to Reflect Red Light

  • Experiment with using red light on white paper with green liquid to simulate chlorophyll. Here is set up. Also used the spectrophotometer.
  • Method appears to work well. This was the best estimate yet and is very close to what I measured as 333 ppm. This spec measured 327 ppm! This time I took three measurements and averaged them to get my R value and used the average to calculate the absorbance. Huge improvement over the other way with paper, since the paper didn’t really look like red or green. Both store and home specs worked equally well. There is some concern that the error is too low, but nevertheless, for my purposes, I think this is the best method. I was very careful mixing solutions and this time took the average of the R values over three trials using the green solution. I like the method much better of using the red light on white paper. Seems to work very well. Store bought spec got similar results. I took three measurements of absorbance at around wavelenth 500 nm. As usual, I chose this wavelength because there was a peak of absorbance around this value with the green food coloring solutions.

Conclusion

My improved cell phone spectrophotometer design gave good results, and the students can use this app and technique to do other types of experiments. I am very excited to have the students use their cellphones to do science, both in the classroom, and outside of it!


[1] “Use Your Smartphone as an “Absorption Spectrophotometer ….” 30 Mar. 2016, https://www.chemedx.org/blog/use-your-smartphone-absorption-spectrophotometer. Accessed 25 Jul. 2017.

[2] “Smartphone “Spectrophotometer” – YouTube.” 30 Mar. 2016, https://www.youtube.com/watch?v=LzYhyXYcs0M. Accessed 25 Jul. 2017.

[3] “How to Calculate Absorbance | Sciencing.” 24 Apr. 2017, http://sciencing.com/calculate-absorbance-2650.html. Accessed 28 Jul. 2017.


pachon-headshotTrudy Pachon teaches AP Biology, AP Environmental Science, Biotechnology, Biology, and Advanced Biology at Mount Everest Academy in SDUSD. She received her B.S. from UCSD in Biology (Evolution, Behavior, and Ecology), a M.S. from UCR in Entomology, and her Master’s in Educational Technology from Boise State University.

 

 

CIAN LECTURE SERIES WEBINAR – Dr. Shayan Mookherjea

Results from the CIAN-Sandia silicon photonic MPW chip: preliminary report

Date: Friday, October 10, 2014
Time: 1:30PM – 3:30PM Pacific Time

Login to the Webinar

Picture1Biography

Dr. Shayan Mookherjea
Associate Professor
Electrical & Computer Engineering
UCSD

Shayan Mookherjea is an Associate Professor of Electrical and Computer Engineering at the University of California, San Diego. He received the BS degree with honors from Caltech, the SM degree from MIT, and the PhD from Caltech in Electrical Engineering with a minor in Physics. His awards include: Wilts Prize, Hellman Faculty Fellow, NSF CAREER award, IEEE Senior Member, and OSA Fellow. The Micro/Nano-Photonics Group (http://mnp.ucsd.edu) started research in silicon photonics in 2008, with 5 PhD theses, 24 journal papers and 47 conference publications so far on these topics, and has active collaborations with several external industrial partners.

Abstract

In 2013, we created an opportunity for five university teams from CIAN [Cornell, Univ. of Arizona, UC Berkeley (2 groups) and UC San Diego] to collaborate with Sandia National Laboratories (Chris DeRose, Tony Lentine, Andrew Pomerene, Andrew Starbuck, Douglas Trotter) in a multi-project-wafer fabrication effort, to design, fabricate and measure optoelectronic silicon photonic components for data center and access networks.

In this talk, I will present some of the results from the first fabrication run, including passive and active waveguides and micro-resonators, thermo-optic tuned filters, variable optical attenuators, Ge detectors, and some examples of sub-system performance. Results from this first run will inform the design of improved components, alongside space for some new designs, in a second fabrication run proposed in the near future.

Please register for “Results from the CIAN-Sandia silicon photonic MPW chip: Preliminary Report” on Oct 10, 2014 1:30 PM PDT at:

https://attendee.gotowebinar.com/register/8835685697665753602

After registering, you will receive a confirmation email containing information about joining the webinar.

2014 10-10 Shayan Mookherjea UCSD

Research Experience for Undergraduates – Apply Today!

REU2013flyer

It’s that time of year again and we’re accepting applications for the Integrated Optics for Undergraduates (IOU) Research Experience for Undergraduates (REU) program.

If you have not heard of the IOU-REU before you can start by watching this video.

To learn more about the IOU-REU program and to apply please visit our website. Here you will also find Continue reading